Return

Use Back buuton on your browser to return. Otherwise click here for Foresoft Home.

Friday, December 6, 2024

Ezigrade 4.0.2.104

When merging a drain we now have the option of creating a new surface with only the drain design in it. Some bug fix's with grading and height constrained points.

Wednesday, October 16, 2024

Ezigrade 4.0.2.88

We now have an option for users to enter there own pipe sizes, that overwrites the calculated values from Ezigrade.

Friday, October 11, 2024

Ezigrade 4.0.2.87

With large pdf reports the summary page didn't extend over more than one page. Now fixed. Also no limit now on the number of setcions that can be reported.

Monday, September 30, 2024

CDS 4.2.0.7

Added in smarter text editting facilities to CDS. Click on entered text and you now have three grip points for move, rotate and scale.

Thursday, September 5, 2024

Ezigrade 4.0.2.73

Ezigrade, when designing a pipe profile. The pipe profile view is now created as a dockable window. What this means is that you can grab the window and drag the view to your second monitor.

Thursday, August 15, 2024

Ezigrade 4.0.2.72

Couple of extra's in Ezigrade Tile Drainage - Pipe stuff. (1) We have added in a new constraint. We can now define a minimum pipe offset. Previously this was zero. Specifying a value here means that for example a lateral is allways a minimum value above the submain or main at the lateral outlet. Simply leave off if you want the old method. (2) We have added in a routine to add in a new node along a pipe. Select the pipe first and then from the pipe menu click on the "add node" menu item and click in the position of the new node. For example if you wanted a more curved section then click in a new point before and after an existing node. Then drag the existing node to match the curve.

Friday, July 12, 2024

Ezigrade 4.0.2.56

When grading sections hinged together. Ezigrade will now make sure the cut/fill ratio and any dirt imported or exported is correct for each section. Previously imported / exported dirt was calculated as a single value over all the hinged sections. (Hope this makes sense!)

Ezigrade 4.0.2.56

Couple of improvements to the outlet routines: (1) If you set the inlet height of the outlet it now disables min and max grades in that area so you can get a smooth join between the outlet and the surface. (2) Outlets now join together. There is no limit to the number of nested outlets. Look at FAQ's under support menu for more details.

Thursday, June 13, 2024

Ezigrade 4.0.2.55

We have added in a menu item to save a pipe network as strings. Helpfull for exporting a pipe network to acad and similar.

Wednesday, May 8, 2024

Ezigrade 4.0.2.54

We have implemented a routine to import LAZ files directly. View the LAZ and import into Ezigrade. Coming to CDS shortly.

Friday, April 5, 2024

Ezigrade 4.0.2.47

Two changes to the the Ezigrade pipe module. When calculating catchment areas we now ignore water that is more than twice the catchment width from the pipe. There was also a bug in the Trim -> perpendicular line. The spacing was getting skinnier.

Tuesday, February 13, 2024

Ezigrade 4.0.2.46

Added a new function to convert State Plane coordinates to UTM coordinates.

Friday, February 9, 2024

Ezigrade 4.0.2.45

Updates to sreamline the design of pipe networks. New features include When extending pipes we can now extend the pipe so it intersects the extending line perpendicular. Ability to draw in a pipe along an arc When copying pipes along a main we have some extra functions.As well as a simple displacement we can now create parallel lines and also draw 'knuckles' to give extra control. Now can design pipe layout in acad or similar and we can import this into Ezigrade. Extra videos and tutorials are coming soon to show how to use these new features.

Tuesday, January 23, 2024

Ezigrade 4.0.2.44

Miscellanous fix's for Pipe reports: (1) total area drained on first page (2) individual areas drained by each pipe (3) OPtion to put out job display in either landscape or portrait mode (4) Display min grade for individual pipes.